Geberit energy retaining valve ERV The pinnacle for a better energy efficiency
The Geberit energy retaining valve ERV seals every last leak
Energy-saving measures are standard features of today’s buildings and are usually applied to the whole structure. Nevertheless, there had always been a missing piece to the puzzle that no one had been able to solve when it came to ventilation for the stack – that is, until the Geberit energy retaining valve ERV came along. When a toilet is flushed, for instance, this kind of opening prevents negative pressure from forming and traps from being blown empty. In the past, the open stack would always result in constant heat losses via the drainage system.
Now, however, the innovative Geberit energy retaining valve ERV makes this problem a thing of the past by:
- only opening when required thanks to its patented diaphragm system
- always ensuring pressure compensation when required
- preventing unnecessary heat losses and thereby increasing the energy efficiency of the building
The economic contribution to climate change mitigation
Positive effects that pay off
Depending on the building structure, location and weather conditions, a Geberit energy retaining valve ERV installation can pay for itself within five to ten years*. People who use roof terrace areas can also benefit from the Geberit energy retaining valve ERV, as it prevents unpleasant odours escaping from ventilation pipes.
- Save energy without losing functionality – up to 50 litres of heating oil per year can be saved in this way*
- Can be mounted onto a diameter of d110 and adapted to suit all common installation methods
- Maintenance-free with protection against insects and frost resistance
*Information based on model calculations using air temperatures in Lucerne (Switzerland) for a multi-storey building and uninsulated stacks.
Here’s how the Geberit energy retaining valve ERV works
Heat loss from the roof
Looking through an infrared camera reveals clear differences in surface temperature, which are especially visible in cold weather.
Appropriate ventilation of sanitary pipelines
The Geberit energy retaining valve ERV seals the ventilation pipe for waste water above the roof using a patented magnetic diaphragm system. This system opens automatically when pressure compensation is required. The rest of the time, it retains heat inside the building. Overpressure from the sewage system can escape via the Geberit energy retaining valve ERV, as the diaphragms open in both directions. The Geberit energy retaining valve ERV therefore meets the requirements of the standard SN 592000.
Visible heat loss without Geberit energy retaining valve ERV
Working on behalf of the Swiss Federal Office of Energy SFOE, the School of Engineering and Architecture at Lucerne University conducted a study on heat loss from functional openings in building shells. Findings from this study show that heat is lost via the weathering slates.
Appropriate ventilation with the Geberit energy retaining valve ERV diaphragm system
Licensors / Project sponsors
OEKAG WasserTechnik AG / Swiss Climate Foundation / Swiss Federal Office of Energy (SFOE)